Custom Pan Pitch Based Carbon Fiber Oxidation Furnace Kiln Oven
description1
01
product introduction
Oxidation furnace/kiln/oven of Yanneng electric heating is to use the principle of converting electrical energy into thermal energy to heat the polyacrylonitrile precursor, so that the fiber will not melt or burn under high temperature carbonization in the following processing. Oxidation treatment can improve the yield and mechanical properties of carbon fibers and continue to maintain the fiber strength. Yanneng oxidation furnace/kiln/oven is mainly composed of electric heating equipment, temperature control parts, heating chamber and accessories.

Oxidation Furnace/Kiln/Oven Parameters
| NO. | Technical Property | Specification | |
| 1 | Input Voltage Furnace/Kiln/Oven: | 380V 50Hz; | |
| 2 | Overall Dimension | 15500×3400×1650(L×W×H) | |
| 3 | Hearth Dimension | 12000×2600×600mm | |
| 4 | Mesh Belt Width | 2500mm | |
| 5 | Mesh Belt Driving Motor | 3.0KW(Variable Frequency) | |
| 6 | Mesh Belt Speeding(Variable Frequency) | Maxium Speeding 400mm/min | |
| Regular Speeding 100—400mm/min(Adjustable) | |||
| 7 | Heating Type | The electric heating tube heats the hot air in a circulation way, and the circulating fan sucks it in and blows air from top to bottom. | |
| 8 | Heating Power | All Power:576KW,12 Heating Areas,Power of Individual Heating Area:48KW | |
| 9 | The Circulation Fan | Fan Quantity | 12 sets |
| Fan Power | 4-72-3.6A 2.2KW/set | ||
| Wind Volume | 1703m3/h(Variable Frequency) | ||
| Wind Pressure | 369pa | ||
| 10 | Temperature | 300℃ | |
| 11 | Working Temperature | regular--300℃(adjustable) | |
| 12 | Temperature Tolerance | ±3℃ | |
| 13 | 升温速度 | 3℃/min | |
| 14 | Temperature Control Point | A double-head temperature measuring thermocouple is used, one for heating zone temperature control (2 temperature control points), and the other for heating zone extreme over-temperature protection (12 extreme over-temperature protection points). | |
| 15 | On-site temperature Testing points | Each heating zone is equipped with on-site temperature testing points and on-site temperature testing instruments, totaling 12 nos | |
| 16 | Air and Nitrogen Inlet | Each Zone is equipped with an independent flow meter and regulating valve for replenishing fresh air. There is a bypass nitrogen pipeline on the main fresh air pipeline. Fresh air is supplied by a high-pressure vortex fan, and the fresh air inlet is located at the central inlet of the hot air circulation fan; the nitrogen outlet is located at the interval of each heating zone, and a horizontal pipeline layout is adopted. All air and nitrogen are controlled by manual valves. Single flow meter flow: 25 cubic meters/hour Total flow: 25 cubic meters × 12 = 300 cubic meters/hour | |
| 17 | Control Mode | PID automatic program control, both manual and automatic | |
| On-site panel operation, PC-side monitoring communication system can be installed according to customer needs; | |||
| Each zone has independent temperature control instrument and over-temperature alarm function | |||
| Alarm form: sound and light alarm; set and display parameters in the temperature controller. | |||
Installation&Service

e-catalogue