China Horizontal Vacuum Electric Heater - High-Quality Suppliers and Factory for Efficient Heating Solutions
Dimensions & Load
- Furnace Chamber Dimension: φ600×1200mm
- Overall Dimension: 2500×1200×1600 mm
- Inside Racks Loading: 300KG
- Equipment Net Weight: ≤2T
- Furnace Shell Temperature: Less than 30℃ at the highest operation temperature (excluding inlet, inlet cover, and some metal conduction parts).
Temperature & Power
- Operation Temperature: Normal~600℃ (adjustable)
- Designing Temperature: 600℃
- Temperature Precision: ±1℃
- Overall Capacity: 42KW
- Temperature Elevation: Adopted of SCR control
Vacuum & Water System
- Vacuum Pump Parameters: Model: 2BV5110 | Inlet/Outlet Diameter: DN50 | Air Displacement: 2.75m³/min
- Vacuum Pump Power Capacity: 2.2KW
- Vacuum Pressure: 0.060~0.085MPa
- Water Consumption: 5~15L/min
- Water Cleaning Time: 1~100h (adjustable)
Control System
- System Interface: Human machine interface, PLC automatic programming temperature control. Runs automatically without human assistance and cuts off as the programming ends.
- Remote Capabilities: Controlled by microcomputer in the electric cabinet. Achieves remote control and remote alarm through communication ports.
- Exhaust Air Control: PLC controlled exhaust air disposal.
Equipped with an internal pressure relief device. In case of fire in the furnace due to pressure loss, it safely relieves internal pressure.
If the temperature goes 10℃ above the limit, the system cuts off power and stops heating. If the water supply is interrupted or water pressure drops below the set value, the vacuum pump stops, control power is automatically cut off, and an alarm is triggered.
Equipped with exhaust gas disposal. Meets national waste water emission standards <Emission Standards of pollutants for synthetic industrial resin> GB31572-2015. Form 1 "indirect emission" standards and the quality water requirements by wastewater treatment plants in industry clusters. Wastewater is centrally treated and discharged by the customer's wastewater treatment system.
Frequently Asked Questions
The operating temperature ranges from normal up to 600℃ (adjustable), with a design temperature of 600℃. The temperature precision is maintained within ±1℃.
If the temperature exceeds the limit by 10℃, the system automatically cuts off the power and stops heating. Additionally, if the water supply is interrupted or water pressure falls below the set value, the vacuum pump stops, the control power is cut off, and an alarm is triggered.
Yes. The equipment is equipped with exhaust gas disposal and meets the national wastewater emission standards <Emission Standards of pollutants for synthetic industrial resin> GB31572-2015, Form 1 "indirect emission" standards.
Yes. The furnace features a PLC automatic programming temperature control system with a human-machine interface that allows it to run automatically without human assistance. It also supports remote control and remote alarms via communication ports.
The inside racks support a loading capacity of up to 300KG. The furnace chamber dimension is φ600×1200mm, and the overall equipment net weight is ≤2T.
The system requires a water consumption rate of 5 to 15L/min, and the water cleaning time is adjustable from 1 to 100 hours.