Horizontal Vacuum Heating Furnace
Furnace Chamber Dimension:φ600×1200mm
Overall Dimension: 2500×1200×1600 mm
Operation Temperature: Normal~600℃(adjustable)
Designing Temperature: 600℃
Overall Capacity: 42KW. Vacuum Pump Power Capacity:2.2KW
Vacuum Pump Parameters: 2BV5110, Inlet Diameter: DN50, Outlet Diameter: DN50. Air Displacement 2.75m³/min.
Vacuum Pressure: 0.060~0.085MPa
It is equipped with pressure relief device inside the furnace: In the case of fire in the furnace due to pressure losing, it can be assured of relieve the inside pressure.
Inside Racks Loading: 300KG
Temperature Precision: ±1℃
Control System: Human machine interface, PLC automatic programming temperature control, the furnace can run automatically once set up without human assistance, cut off as the programming ends.
Temperature elevation is adopted of SCR control
Over Temperature Protection: As the temperature goes 10℃ above the limit, The system will cut off the power and stop heating. As the water supply is interrupted or the water pressure drops below the set value, the vacuum pump stops working, the system automatically cuts off the control power, and an alarm is triggered.
Exhaust air disposal control: PLC
All equipment is controlled by micro computer in the electric cabinet.Through communication ports, it achieves remote control and remote alarm.
The equipment is equipped with the exhaust gas disposal.
Meeting national waste water emission standards< Emission Standards of pollutants for synthetic industrial resin>. GB31572-2015. Form1”indirect emission” standards and requirement of quality water by wastewater treatment plants in industry cluster.The wastewater is then centrally treated and discharged by the customer's wastewater treatment system.
Water Consumption:5~15L/min.
Water Cleaning Time:1~100h(adjustable)
The furnace shell temperature is less than 30℃ at the highest operation temperature. (not including inlet, inlet cover and some metal conduction parts)
Equipment net weight:≤2T.